Skip to main content
simply more productive

The Data Specialist

Thanks to our intuitive transformation designer, you can convert data effortlessly to a variety of formats without knowing how to program. It’s not only efficient, it’s also easy to use.
Flowheater Download

Clone Heater, copying, cloning and duplicating fields

Clone HeaterThe Clone Heater has three possible uses:

  1. Copy or duplicate the content in a field for potential multiple uses as input for other Heaters.
  2. Copy or duplicate the content in a field in order to achieve a clearer visual layout in the Designer.
  3. Debug results of the content using the Test and Run popup.

For 1) A field serves as a single input for a Heater. However, it may be necessary to provide the same field’s content as input more than once to Heaters. This can be achieved using the Clone Heater, which acts solely as a neutral facilitator. No data in the original field gets amended and an exact copy of the field contents and data type is carried forward.

For 2) In a more complex Definition with many Pipes (connections) it can become difficult to see the structure easily. However, by using the Clone Heater you can reroute Pipes to where there is more space on the Designer, in the simplest possible way. To do this you invoke the context menu for the Pipe (right mouse button with the cursor positioned over the Pipe) and click on the menu option "Insert Clone Heater". The Pipe will then be automatically divided at the mouse position and a Clone Heater inserted between the two new segments.

Clone Heater, Debug Output
Clone Heater, Debug Output

For 3) To track down errors and discover why a field is not being converted as expected, you can set the Debug output option active for the Clone Heater. In this way you indicate to FlowHeater that the content of the field is to be reported in the debug section in the Test and Run popup. The Identifier enables you to establish labels to clearly distinguish between several of debug reports, with the actual value reported alongside it in the debug output.

Note: In the Test and Run popup you must also confirm that “Debug output” is active.

 

Please also refer to the general information on the use of Heaters (functions)

FlowHeater - The Data Specialist

Efficient data integration and transformation with FlowHeater – the perfect solution for a seamless transfer of your data.

Rechtliches

Support & Contact

Kontaktinformation

Telefon:0951 / 99339792 E-Mail:This email address is being protected from spambots. You need JavaScript enabled to view it.

Copyright © 2009-2024 by FlowHeater GmbH. All rights reserved.